Light exposure can alter some types of chemotherapy drugs, such as Carboplatin, Cisplatin, Fluorouracil, Anthracyclines, being them photosensitive. For this reason, it is important to protect them with devices avoiding this type of problem.
The solution adopted has been to create devices using pigmented materials with amber colouring allowing to selectively stop the wavelengths that might modify the drug.
Through laboratory tests we evaluated the transmittance (i.e. the relationship between incident and emerging light flow passing through a substance) and absorbance (i.e. the ability of a substance to absorb a light source). The results have been reported in the next diagram: from this we may understand the obtained shielding high power in the wavelengths between 200 and 600 nm.
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308AA | 1 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308BA | 2 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308CA | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308LA | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 0,2 μm | Sì | No | 50 |
ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308GA | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308HA | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
INFUSION POINT WITH SELF-SEALING VALVE
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | IMBALLO |
---|---|---|---|---|---|---|
MCI/308AAY | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308BAY | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308CAY | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/309BANL | 2 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | No | Sì | 50 |
MCI/309CANL | 4 | Ø16 x 70mm - FILTRO 15 μm | 2 WAY – FILTER 1,2 μm | No | Sì | 50 |
ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK
INFUSION POINT WITH SELF-SEALING VALVE
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/309AAY | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
EQUIPPED WITH 3-WAY TAP WITH SELF-SEALING VALVE AND SWIVEL LLM
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308DA | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308EA | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308EA | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308DANL | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308EANL | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308FANL | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |