Administration Photosensitive Drugs

Light exposure can alter some types of chemotherapy drugs, such as Carboplatin, Cisplatin, Fluorouracil, Anthracyclines, being them photosensitive. For this reason, it is important to protect them with devices avoiding this type of problem.
The solution adopted has been to create devices using pigmented materials with amber colouring allowing to selectively stop the wavelengths that might modify the drug.
Through laboratory tests we evaluated the transmittance (i.e. the relationship between incident and emerging light flow passing through a substance) and absorbance (i.e. the ability of a substance to absorb a light source). The results have been reported in the next diagram: from this we may understand the obtained shielding high power in the wavelengths between 200 and 600 nm.

ADMNISTRATOR FOR PHOTOSENSITIVE DRUGS IN PVC

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYS
MCI/308AA1Ø16 x 70mm - FILTER 15 μm2 WAY – FILTER 1,2 μmNo50
MCI/308BA2Ø16 x 70mm - FILTER 15 μm2 WAY – FILTER 1,2 μmNo50
MCI/308CA4Ø16 x 70mm - FILTER 15 μm2 WAY – FILTER 1,2 μmNo50
MCI/308LA4Ø16 x 70mm - FILTER 15 μm2 WAY – FILTER 0,2 μmNo50

ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK


ADMNISTRATOR FOR PHOTOSENSITIVE DRUGS IN PVC

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYS
MCI/308GA2Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308HA4Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50


ADMNISTRATOR FOR PHOTOSENSITIVE DRUGS IN PVC

INFUSION POINT WITH SELF-SEALING VALVE

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYSIMBALLO
MCI/308AAY1Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308BAY2Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308CAY4Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50


ADMINISTRATOR FOR PHOTOSENSITIVE DRUGS IN POLYURETHANE

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYS
MCI/309BANL2Ø16 x 70mm - FILTER 15 μm2 WAY – FILTER 1,2 μmNo50
MCI/309CANL4Ø16 x 70mm - FILTRO 15 μm2 WAY – FILTER 1,2 μmNo50

ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK


ADMINISTRATOR FOR PHOTOSENSITIVE DRUGS IN POLYURETHANE

INFUSION POINT WITH SELF-SEALING VALVE

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYS
MCI/309AAY1Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50


ADMNISTRATOR FOR PHOTOSENSITIVE DRUGS IN PVC WITH FLOW REGULATOR

EQUIPPED WITH 3-WAY TAP WITH SELF-SEALING VALVE AND SWIVEL LLM

CODEWAYSDRIP CHAMBERSPIKEN.R.V. IN THE LATERAL WAYSSELF-SEALING VALVE IN THE LATERAL WAYS
MCI/308DA1Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308EA2Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308EA4Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308DANL1Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308EANL2Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50
MCI/308FANL4Ø16 x 70mm - FILTER 15 µm2 WAYS - FILTER 1,2 µmNo50