In addition to standard solutions, the particularity and multiplicity of oncological therapies require variants that allow to match ward and patient needs, while combining efficacy and safety.
In fact, there are many parameters to consider, as the incompatibility of some drugs with PVC, the protection of photosensitive drugs, the use of valves self-sealing and / or one way, the presence of the 3-way stopcock with self-sealing valve.
The result of this work of research along with the advice from professionals is a combination of factors that makes the product line complete, safe, and reliable.
Continuous attention andresearch to offer operators the best therapeutic opportunities.
Administrators:
– standard in PVC
– for photosensitive drugs
– in PU for drugs incompatible with PVC
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308A | 1 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308I | 1 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 0,2 μm | Sì | No | 50 |
MCI/308B | 2 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308C | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308L | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 0,2 μm | Sì | No | 50 |
MCI/308ANL | 1 | Ø16 x 70mm - FILTRO 15 µm | 2 WAY - FILTER 0,2 µm | No | Sì | 50 |
ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308G | 2 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
MCI/308H | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | Sì | No | 50 |
INFUSION POINT WITH SELF-SEALING VALVE
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308AY | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308BY | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308CY | 3 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/309BNL | 2 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | No | Sì | 50 |
MCI/309CNL | 4 | Ø16 x 70mm - FILTER 15 μm | 2 WAY – FILTER 1,2 μm | No | Sì | 50 |
ALL CODES ARE PROVIDING 3 WAY STOPCOCK WITH SELF-SEALING VALVE AND ROTATING MALE LUER LOCK
INFUSION POINT WITH SELF-SEALING VALVE
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/309AY | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
EQUIPPED WITH 3-WAY TAP WITH SELF-SEALING VALVE AND SWIVEL LLM
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/308D | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308E | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308F | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | Sì | No | 50 |
MCI/308DNL | 1 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | No | Sì | 50 |
MCI/308ENL | 2 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | No | Sì | 50 |
MCI/308FNL | 4 | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 1,2 µm | No | Sì | 50 |
CODE | WAYS | DRIP CHAMBER | SPIKE | N.R.V. IN THE LATERAL WAYS | SELF-SEALING VALVE IN THE LATERAL WAYS | ![]() |
---|---|---|---|---|---|---|
MCI/302F | - | Ø16 x 70mm - FILTER 15 µm | 2 WAYS - FILTER 0,2 µm | No | Sì | 50 |